Yes, in most homes a single front door with two sidelights can become a pair of doors, and often in the same opening. A 36-inch door with two 12- or 14-inch sidelights takes up about as much wall as a pair of 30- or 32-inch doors. A pair of 36-inch doors needs a wider opening and a new header.
This guide shows how to tell which case you're in, what the work involves for each, what the Georgia building code asks of a front door, and which parts of the job a homeowner can do.

The short version
- Your sidelights are your head start. The frame that holds a door and two sidelights is already wide. Swapping it for a pair of doors usually means no new header and no brick work.
- The width of the sidelights decides the size of the pair. Narrow 10-inch sidelights leave room for less than a 5-foot pair. 12-inch sidelights fit a pair of 30-inch doors. 14-inch sidelights fit a pair of 32-inch doors.
- A 6-foot pair (two 36-inch doors) almost always means widening the opening: a new header, new framing, a steel lintel in brick, interior drywall and trim, and a building permit.
- A transom above the door is extra height. Taking it out can make room for taller 8-foot doors without touching the width.
- Check the egress rule before you pick narrow doors. The Georgia code wants one exterior door with 32 inches of clear width. If the front door is your only hinged exterior door, that matters.
Will a double door fit where your door and sidelights are now?
Door makers publish the rough opening each unit needs. The rough opening is the framed hole in the wall, from stud to stud and from the subfloor to the header. Compare the opening your current door and sidelights need with the opening a pair of doors needs, and you know whether the swap fits.
These figures are from Therma-Tru's unit and rough opening sizing chart for inswing units with standard 6'8" doors, with Masonite's figures where it publishes the same configuration:
| Unit | Unit width | Rough opening width (Therma-Tru) | Rough opening width (Masonite) |
|---|---|---|---|
| 36" door with two 10" sidelights | 59 1/2" | 60 1/4" | – |
| 36" door with two 12" sidelights | 63 1/2" | 64 1/4" | 65 1/4" |
| 36" door with two 14" sidelights | 67 1/2" | 68 1/4" | – |
| Pair of 30" doors (5'0") | 62 3/16" | 62 15/16" | – |
| Pair of 32" doors (5'4") | 66 3/16" | 66 15/16" | – |
| Pair of 36" doors (6'0") | 74 3/16" | 74 15/16" | 74 3/4" |
Read the table from your starting point:
- 36-inch door with 10-inch sidelights (about 60 inches): even a 5-foot pair needs about 3 more inches. The opening has to be widened a little, or you choose a wider single door instead (see other ways to get a bigger entry).
- 36-inch door with 12-inch sidelights (about 64 inches): a pair of 30-inch doors fits with room to shim. A 5'4" pair needs about 3 inches more.
- 36-inch door with 14-inch sidelights (about 68 inches): a pair of 32-inch doors fits.
- Any of them to a 6-foot pair: you need 7 to 15 more inches of opening. That is a structural change.
The heights match. A 6'8" pair and a 6'8" door with sidelights need the same rough opening height, 82 inches on Therma-Tru's chart and 82 1/8 inches on Masonite's.
Two cautions. Not every door is 36 inches, and not every sidelight is a stock width; older and custom units vary. And the table compares rough openings, which you can only see with the trim off. Our double front door sizes guide shows how to measure your opening, step by step.

The three ways the job can go
1. Same opening, new pair of doors
This is the common case when the sidelights are 12 inches or wider. We take out the old door, both sidelights and the frame they share, check the framing for rot and level, and set a pre-hung double unit in the same opening. Shims, new exterior trim and interior casing finish it. The header, the brick and the wall stay as they are.
What changes on the outside: the brickmould or trim around the opening, and the sill. Inside: new casing, and sometimes touch-up paint where the old casing sat.
2. Same width, taller doors (transom out)
Many entries with sidelights also have a transom, the window above the door. If you take out the transom along with the sidelights, the opening gets taller as well as being reused for width. That can make room for 8-foot doors, which suit two-story foyers. Therma-Tru builds its double units in 6'8", 7'0" and 8'0" heights. Masonite's chart shows a 36-inch door with two 12-inch sidelights and a rectangular transom needs a rough opening 95 3/4 inches tall, compared with the 98 1/2 inches Therma-Tru lists for an 8-foot inswing unit, so the transom opening is close but not always enough. Measure it before you decide.

An arched transom like the one above can stay. Arch-top double doors are made to fit a curved opening, or the arch can be kept as glass above a square-top pair.
3. Wider opening for a 6-foot pair
If you want two full 36-inch doors and your opening is 60 to 68 inches wide, the wall has to open up. This is what that involves:
- A new header. The header is the beam over the opening that carries the wall, floor or roof above it. A wider opening needs a deeper header. The building code sizes it by the width of the opening, the width of the house, the snow load and what the wall carries (2024 International Residential Code, section R602.7).
- New framing at each side. Jack studs under each end of the header and full-height king studs beside them. Wider openings need more jack studs.
- A steel lintel in brick veneer. On a brick front, the brick above the opening sits on a steel angle, not on the wood header. A wider opening needs a longer lintel with at least 4 inches of bearing on each side, and the brick at both sides has to be cut and toothed back in.
- Interior drywall, trim and flooring around the new opening.
- A wider landing. The code wants the landing or stoop outside an exterior door to be at least as wide as the door (more on that below).
- A building permit. The code requires a permit before anyone alters a building's structure, and widening an opening in a bearing wall is structural work. Your city or county building department issues it.

It is a bigger job, with more trades involved, but it's a common one. We'll tell you at the measure whether your wall can take it and give you a written price for each option.
What the Georgia building code asks of a front door
Georgia's state minimum code for houses is the 2024 International Residential Code with Georgia amendments, in effect since January 1, 2026. Three of its rules matter when you go from one door to two.
| Rule (2024 IRC) | What it says | What it means for a double door |
|---|---|---|
| Egress door, R318.2 | Every house needs at least one side-hinged egress door with at least 32 inches of clear width (door open 90 degrees, measured face of door to stop) and 78 inches of clear height. Other exterior doors don't have to meet these minimums | A 36-inch door gives about 32 inches clear. A 30- or 32-inch leaf on its own gives less. The code text measures one door and doesn't say whether two leaves can count together |
| Landings, R318.3 | A landing or floor on each side of each exterior door, at least as wide as the door it serves and at least 36 inches deep in the direction you walk | A wider pair of doors needs a stoop or porch at least as wide as the pair |
| Threshold, R318.3.1 | At the required egress door, the landing can be at most 1 1/2 inches below the top of the threshold (up to 7 3/4 inches outside if the door doesn't swing over it) | A new inswing pair sits on the same rules as the door it replaces |
What to do about the 32 inches: most houses also have a back door, patio door or garage entry door that is side-hinged. That door can be the one that meets the egress rule, and then the front pair doesn't have to. If the front door is your only side-hinged exterior door and you want narrow leaves, ask your building department how they read the rule before you order. Inspectors differ on whether both leaves of a pair can count.
Active and passive doors: how a pair works
Most double front doors are a French pair: one active door with the lockset and deadbolt, and one passive door held shut by flush bolts into the head and the sill. A strip called an astragal covers the gap where they meet. Open the bolts and both doors swing, which is what makes a pair useful for moving furniture.
Some "double door" units are really one door and a fixed panel that looks like a door. Therma-Tru sells both: a French pair with an astragal, and a door-and-fixed-panel unit with a mullion between them. The fixed panel can't open. Ask which one you're being quoted.

A few things to decide about the pair:
- Which side is active. The active door should be the one you reach first from the driveway or walk, and it shouldn't swing into a wall switch or a stair.
- Inswing or outswing. The makers' charts list different rough opening heights for each, so decide before anyone orders.
- Hardware. Use a handle set with a deadbolt on the active door and a matching dummy handle on the passive door. A multi-point lock, which latches at the top, middle and bottom, pulls a tall pair tight against the weatherstrip.
- Glass. Full-glass and three-quarter-glass pairs bring in the light the sidelights used to. Textured or decorative glass keeps privacy.
Materials for a double front door
The material changes how a pair looks, how much care it needs and how it handles a south- or west-facing entry in a Georgia summer. Each has its own page, and our guide to energy-efficient entry doors covers glass and weatherstripping:
- Fiberglass takes paint or a woodgrain stain and needs little upkeep. See fiberglass entry doors.
- Wood is the traditional choice for a stained pair, and it needs refinishing on a schedule. See wood entry doors.
- Steel takes a painted finish. See steel entry doors.
- Wrought iron pairs, with glass behind the scrollwork, suit stone and stucco homes. See wrought iron entry doors.

How the conversion goes, step by step
- Measure visit. We take the trim off one side if needed, measure the rough opening, the jamb depth and the height, look at the header and the framing, and check how much room the landing has.
- Choose the pair. Size first, then material, glass, color and hardware. If the pair needs a wider opening, you get the price for both options in writing.
- Order. Pre-hung double units are built to size.
- Remove the old unit. Door, sidelights, transom if it's coming out, and the shared frame. We check the subfloor and the framing at the sill for rot, which is common where a sidelight has leaked.
- Frame. Same-opening jobs get shimming and blocking. Widened openings get the new header, studs, lintel and brick work.
- Set, flash and seal. The unit is leveled, plumbed and squared, then flashed and sealed the way the manufacturer's installation instructions call for, so rain runs out and away from the sill.
- Trim and hardware. Exterior trim, interior casing, the lockset and flush bolts, and an adjustment so the two doors meet evenly at the astragal.
- Walk-through. We show you how the passive door's bolts work and check that both doors close and lock without pushing.
What you can do yourself, and what to leave to a pro
| Job | DIY? | Why |
|---|---|---|
| Measure your door, sidelights and jamb depth | Yes | It tells you which row of the sizing table you're in. Our sizes guide shows how |
| Pick styles, glass and colors | Yes | Browse the entry door gallery for pairs on homes like yours |
| Paint the passive door's flush bolts, swap a handle set later | Yes | Ordinary hardware work |
| Remove a door and sidelights, set a pre-hung pair in the same opening | Experienced DIYers only | A double unit is heavy and has to be square to within a fraction of an inch, or the doors won't meet at the astragal. Flashing mistakes show up later as rot |
| Widen the opening, new header, lintel and brick | No | Structural work in a bearing wall, and it needs a permit |
| Decide whether narrow leaves meet the egress rule | Ask the building department | Their reading of the rule is the one that counts |
If a double door doesn't fit
When the opening is narrow, or the budget points away from a new header, these keep most of the look:
- A wider single door. Therma-Tru makes single doors up to 42 inches wide. A 42-inch door with narrow sidelights makes a broad entry without a pair.
- New sidelights with more glass. Replacing the door and sidelights as one new unit changes the look of the entry with no framing work.
- Add or enlarge a transom above the door for height and light.
- A door and fixed panel that reads as a pair from the street, in the same opening as your current unit.
Going the other way, from a pair to a single door with sidelights, uses the same sizing table in reverse. A 6-foot pair's opening takes a 36-inch door with two 14-inch sidelights plus a little framing, for example.
What a conversion changes in Metro Atlanta homes
Many of the brick colonials and traditional homes we work on around Atlanta, Marietta, Roswell and Alpharetta have a single door and sidelights under a portico. A few things come up often on these jobs:
- Brick returns. On a same-opening swap the brick stays. On a widened opening the brick on each side is cut back, and matching old brick takes time.
- Rot at the sidelight sills. Sidelights that have leaked for years can leave soft subfloor at the corners. We find it when the old unit comes out and repair it before the new pair goes in.
- Porch and stoop width. A wider pair can run past a narrow stoop. Check the stoop against the code's landing rule before you choose.
- Afternoon sun. A west-facing pair in a dark color gets hot. Ask about the finish and the material for that exposure.
Our Atlanta front door replacement page covers the rest of the work we do on front entries, and we have a page for entry doors in Alpharetta.
When to call us
Call us when you're ready to find out which row of the table your entry is in. We measure the opening, check the framing and the landing, and give you a written price before any work starts, for a same-opening pair and, where it applies, for a widened opening. All Four Seasons has worked on Metro Atlanta homes since 1999, we're rated 4.9 on Google with Over 4,000 Five-Star Reviews, and our office is open seven days a week, 7 AM to 8 PM.
Call (678) 271-8918 or book a measure online. You can also see our entry door services.
Frequently asked questions
Can you replace a single front door with sidelights with a double door?
Yes, in most homes. A 36-inch door with two 12-inch sidelights uses about the same rough opening as a pair of 30-inch doors, and with 14-inch sidelights a pair of 32-inch doors fits. Only a pair of 36-inch doors usually needs a wider opening.
How much space do you need to go from a single door to a double door?
A pair of 30-inch doors needs a rough opening about 63 inches wide; a pair of 32-inch doors about 67 inches; a pair of 36-inch doors about 75 inches, on Therma-Tru's chart. A single 36-inch door alone needs about 38 inches, so without sidelights you'll be widening the wall.
Do I need a new header to install double front doors?
Not if the pair fits the existing opening, which is common when you're replacing a door with sidelights. If the opening gets wider, yes: the header has to be sized for the new span, with new jack studs and, on a brick home, a longer steel lintel.
Do I need a permit to convert to a double door?
For a same-size replacement, ask your city or county building department whether it needs one. Widening the opening in a bearing wall is structural work, and the building code requires a permit for it.
Are double front doors less secure than a single door?
The passive door is held by flush bolts at the top and bottom, and the active door locks into it. Strong flush bolts, a reinforced astragal and a multi-point lock that latches at several points keep a pair tight. Ask about all three when you choose the doors.
Can I keep my transom when I switch to double doors?
Yes. A pair of 6'8" doors fits under most existing transoms. You only take the transom out if you want taller doors in its place.
Can I go back from double doors to a single door with sidelights?
Yes. A 6-foot pair's opening fits a 36-inch door with two 14-inch sidelights after minor framing. The same sizing tables apply in reverse.